You must be an Incathlab member to access videos without any restrictions. Register for free in one minute and access all services provided by Incathlab.You will also be able to log into Incathlab from your Facebook or twitter account by clicking on login on the top-right corner of Incathlab website.

Registration Login


16702 views

Clinical data

  • 61 year old man
  • Left IF DVT 2015
  • Swollen leg since
  • Reent development obvious PTS LLE
  • Venous Claudication
  • No ulceration or swelling

1st Plan

  • R IJV access 10F 23cm Cordis Brite tip
  • Access L groins CFV/PFV/FV- 5F sheath
  • 5000 u IV Heparin
  • Venography- AP and Lateral
  • Cross from above or below with Cook Tri-Force
  • Glide wires (Terumo) or Roadrunner (Cook)

2nd Plan

  • One “across” use 260 Lunderquist wires through and through
  • CRITICAL TO DETERMINE INFLOW
  • IVUS essential
  • Pre dilate to
    • 16mm CIV
    • 14mm EIV/CFV

3rd Plan

  • Stents: 16mm CIV 14mm EIV CFV
  • Post dilate to nominal diameter stent
  • IVUS to confirm adequate stent expansion
  • Cone Beam CTV

Post operation

  • Calss 2 thigh high compression stockings x 6/52
  • Pneumatic compression boots x 24h
  • Maintain full anticoagulation
  • Colour Doppler US day to confirm stent patency
Shooting date : 2016-12-12
Last update : 2021-06-09
Stephen Black
London, United Kingdom
Rick De Graaf
Maastricht, Netherlands
2 comments
Join the Discussion
  • WEI W. don't you worry about the venous demage if you post dilate to the nominal diameter stent?

      Please, select your files, click upload button, write your comment and click the send button. (allowed formats : images jpeg, gif, png, and PDF)
      Your browser doesn't have Flash, Silverlight or HTML5 support.


    • Olivier H. It must be done this way if you use the good stent 16-18 mm for CIV, 14-16 mm for EIV and CFV

        Please, select your files, click upload button, write your comment and click the send button. (allowed formats : images jpeg, gif, png, and PDF)
        Your browser doesn't have Flash, Silverlight or HTML5 support.


      Suggestions

      May 2012
      Honolulu : Wednesday, May 9th 2012 from 05am to 07:20am (GMT-10)
      San Francisco : Wednesday, May 9th 2012 from 08am to 10:20am (GMT-7)
      New York : Wednesday, May 9th 2012 from 11am to 01:20pm (GMT-4)
      Buenos Aires : Wednesday, May 9th 2012 from 12pm to 02:20pm (GMT-3)
      Reykjavik : Wednesday, May 9th 2012 from 03pm to 05:20pm (GMT)
      London / Dublin : Wednesday, May 9th 2012 from 04pm to 06:20pm (GMT+1)
      Paris / Berlin : Wednesday, May 9th 2012 from 05pm to 07:20pm (GMT+2)
      Istanbul : Wednesday, May 9th 2012 from 06pm to 08:20pm (GMT+3)
      Moscou / Dubaï : Wednesday, May 9th 2012 from 07pm to 09:20pm (GMT+4)
      Bangkok : Wednesday, May 9th 2012 from 10pm to 12:20am (GMT+7)
      Shanghai : Wednesday, May 9th 2012 from 11pm to 01:20am (GMT+8)
      Tokyo : Thursday, May 10th 2012 from 12am to 02:20am (GMT+9)
      Sydney : Thursday, May 10th 2012 from 02am to 04:20am (GMT+11)
      Wellington : Thursday, May 10th 2012 from 04am to 06:20am (GMT+13)

      Abbott Vascular Knowledge Center Education Program: CLI complex case management Live cases

      from Abano Terme with Dr. Marco Manzi -

      Share

      CLIC 2019: Live Case #1

      Dr Shannon D. Thomas, Dr Elena Herrero & Dr Luis Mariano Palena

      Share
      Scroll Up